What the manufacturer’s HPMA sheet actually specifies
Start with the HPMA technical data sheet issued by Jiyuan Qingyuan Water Treatment Co., Ltd. (PDF). It identifies the product as liquid hydrolyzed polymaleic anhydride, also called homopolymer of maleic acid, CAS 26099-09-2. Use the full name and CAS on your purchase specification. That gives the laboratory, the supplier and your receiving team the same chemical to look up.
| Property | Manufacturer’s sheet | What to carry into the RFQ |
|---|---|---|
| Viscosity | 6.0 mm²/s minimum | The unit identifies kinematic viscosity. Request the test method and temperature. |
| Density | 1.22–1.25 g/cm³ at 20°C | The 20°C condition applies to the density row. |
| Solids | 50.0% minimum | Record this as solids content and agree on the method for lot acceptance. |
| Bromine value | 80 mg/g maximum | Keep the unit and the upper limit together. |
| pH | 2.0–3.0 in a 1% solution | Specify the same dilution when requesting a comparison. |
The sheet gives no temperature or method on the viscosity line. The proximity of the density line makes it easy to copy 20°C onto both rows. A buyer doing that would be adding a test condition the manufacturer has yet to confirm. If viscosity is a release criterion at your plant, send your lab’s temperature and method to the supplier before putting that limit on the order.
Which numbers can you compare directly?
A centistoke (cSt) equals one square millimeter per second (mm²/s). Those are two ways to express the same quantity, kinematic viscosity. A centipoise (cP) equals one millipascal-second (mPa·s), a unit of dynamic viscosity. Changing the label from cSt to mm²/s leaves the number unchanged. To relate a cP reading to a cSt value, you also need the density of the liquid. The NIST unit conversion tables list both families of units.
For comparable measurements on a Newtonian liquid, divide dynamic viscosity in cP by density in g/cm³ to obtain kinematic viscosity in cSt. This viscosity calculation in a NIST-hosted technical report (PDF, p. 17) shows the units used in the relationship. Use density measured on the same sample at the viscosity test temperature. For example, a 25°C viscosity result needs a 25°C density. The supplier’s published density range lets your lab check whether a density result at 20°C falls within the grade limits. Picking the midpoint of that range to convert a result at 25°C introduces an assumption precisely where your purchasing decision needs a measurement.
If a laboratory reports a reading from a rotational viscometer, ask for the instrument, spindle or geometry, speed or shear rate, temperature and sample preparation. A reading that changes with shear is an apparent viscosity at the reported conditions. Converting its units does not establish that a capillary test on the sample will give the same result. When the two labs cannot establish equivalence, the simplest route is to have them measure the material by the same agreed procedure.
A worked example with two supplier offers
Imagine your plant requires at least 6.0 mm²/s at 25°C by its approved procedure. The temperature in this example belongs to the buyer. The offers and sample values below are illustrative.
Offer A. The supplier quotes a guaranteed minimum of 6.0 mm²/s and attaches a sheet with no viscosity test temperature. The figure matches your limit on paper. Ask whether the supplier can commit to 6.0 mm²/s at 25°C by your procedure, then obtain that condition in writing. Until then, keep the offer open for clarification. A missing test condition tells you nothing about whether the liquid itself would pass.
Offer B. The supplier reports 6.0 cP on its sample at 25°C and a measured density of 1.24 g/cm³ on that sample at 25°C. Assume the labs have established that the sample behaves as a Newtonian liquid under these tests and that your procedure accepts the conversion. The calculation is 6.0 ÷ 1.24 ≈ 4.8 cSt, equivalent to about 4.8 mm²/s. This sample falls below the buyer’s 6.0 mm²/s minimum. Record that finding against the sample tested. If the supplier proposes another grade or batch, ask for a result tied to that material.
One offer needs a missing condition and the other supplies enough information to make a sample decision. Recording those outcomes separately gives purchasing a clear next step for each supplier. It also avoids treating a result from a single drum as a guarantee for future shipments.
What if both samples meet the 50% solids minimum?
Solids and viscosity answer different receiving questions. Two samples can meet the same solids minimum and still have different measured viscosities. If your incoming specification calls for both, keep two entries on the comparison sheet. For each, capture the agreed limit, the supplier’s test procedure, the sample or lot ID and the measured result. A certificate that simply repeats “50.0% minimum” gives you the grade requirement. If your lab needs the result for that particular lot, request the measured solids value.
Once the material meets the incoming specification, a formulator may still need to qualify it for service. Choose an endpoint relevant to your water, such as carbonate deposit formation under the intended cooling-water conditions. Compare the candidate and your existing treatment under the same conditions and document the acceptance criterion before the trial. Viscosity and solids help you identify the grade received. The application trial answers whether it performs the job your plant needs. The polymer sample selection guide covers that separate decision for HPMA, PAA and QSY3100.
An RFQ your receiving lab can use
Before comparing prices, have purchasing and quality agree on which measurements will release a shipment. Send the supplier the applicable method or the parts it needs to review, including revision, temperature and reporting units. Ask the supplier to identify any differences in its normal procedure when it quotes. This is easier to resolve while a sample is still available to both laboratories.
Please quote liquid hydrolyzed polymaleic anhydride (HPMA), CAS 26099-09-2, for delivery to [city, state and ZIP code]. The quantity is [net quantity and unit]. We require [kinematic or dynamic viscosity, limit and unit] at [temperature] by [method and revision], with solids of [limit and unit]. Please confirm which limits you can guarantee. For the evaluation sample, provide the sample ID, measured values, units, methods and temperatures. If you propose a viscosity conversion, include the density measured on that sample at the same temperature.
When the order is placed, keep the accepted specification with the purchase order. On arrival, match the drum or IBC lot number to the certificate of analysis (COA). If the certificate reports a different unit or omits a required temperature, ask for the underlying result or a retest under the agreed conditions before releasing the lot. That gives the receiving team a documented decision even if a different buyer negotiated the order.
Jiyuan Qingyuan manufactures this HPMA in China. H2Q INC. handles U.S. requests for quotations, documents and samples. You can review the HPMA grade specifications or verify the manufacturer and product documents before sending your requirements.